<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22358</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: "Conveyor stopped. Make sure the guard rail gate &amp; drop leaf are closed"
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Also check conveyor interface panel.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check gate is properly closed, check table drop leaf is secure,
check conveyor interface panel is properly in and locked underneath,
check all abort switches and panels.
</text></DescriptionText>
</OperatorAction>
<Cause>
The safety loop belonging to the extended autoloading
electronics is open. Check all safety switches.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/conv.xml</LinkAddress><LinkTitle>Command: conv</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:07 2008 PST
</Updated>
<Links>
</Links>
</Error>